Function Features:
1. Test Battery Pack Capacity;
2. Charge to Battery pack;
3. Discharge Battery pack
4. Charge-discharge-charge automatic cycle
5. Test Battery Power Charger current
6. Test circuit board overcharge and over discharge parameters
7. Built-in Power Supply 1-90V / 1-15A or 20A
8. It can store 30 sets of recent test data in the equipment.
9.Support battery types: Lead-acid battery, Lithium-iron battery, Ternary battery and Li-Polymer battery • Accurate and constant current discharge from 1A-100A over the whole process (maximum of discharge current differs due to different models, so please refer to the machine nameplate for specific parameters ), and input voltage range: 2VDC~100VDC. • Applicable battery pack: Single large monomer!12V!24V!36V!48!60V!72V!84V. • Manage different battery by category, setting safe discharge voltage manually and automatically to effectively prevent battery over-discharge. • Friendly human-machine interface with rich applications for charge and discharge management to flexibly set various charge and discharge parameters. • Accurately record final voltage and capacity of charge and discharge to judge the capacity and quality of battery. • Management of charge and discharge: manage the charge and discharge of battery via internal or external charger (different model configurations), such as displaying and recording charging current, voltage, time, charging capacity, etc. • Display accuracy: +1%, display two decimal places of current and voltage for accurate and intuitive measurement. • Reverse connection of battery input protection and over temperature protection
Technical Parameters:
• Input voltage range: 2VDC-100VDC
• Voltage accuracy: "0.5% ,two decimal places
• Maximum discharge current: 100A • Stepping regulation current: 1A
• Charging voltage: 1-90V, step: 0.1V
• If power supply is 220V the charging current: 1-20A, Step: 0.1A
• if power supply is 110V the charging current: 1-15A, Step: 0.1A
• Maximum charging current: internal charger model - 20A, external charger model - 30A
• Current accuracy: +1%, two decimal places • Charging mode: constant current discharge
• Final voltage of charge: final voltage of charge being set; Automated: Minimum protection voltage of the battery pack-2V or low voltage protection of the battery pack
• Final voltage of discharge: final voltage of discharge being set; Automated: <0.3A,the instrument stops charging
• Capacity testing accuracy: +0.05AH • Heat dissipation method: double roller high-speed cooling fan
• Equipment power supply: AC220V
• Appearance size: 100A model L*W*H:603mm*428mm*609m